Sun Pack

Sun Pack

SUN PACK (Hybrid Home UPS)

Sunpack is a solar hybrid inverter which utilizes solar power as primary source and Grid power as secondary source to charge the batteries. 
Sunpack is designed to give you the maximum advantage from the sun and reduces your electricity cost.
As Sunpack and solar panel do not produce harmful gases and residue, it helps in keeping the environment clean and healthy / eco-friendly.
 
Key Features
 
Sine Wave Output
Preference to Solar Power over Grid power for charging batteries
Can operate without Solar Panel also
Any battery option
Extensive electronic protections
Affordable and easy to install
Longer battery life
 
 
 

Specification


PARAMETERS   UNITS 150,300,500,800 VA (12V) 800,1200,1500VA (24V)
OPERATION LOGIC
 
First priority   Solar charging Solar charging
Second priority   Solar + Grid charging (if PV low) Solar + Grid charging (if PV low)
Third priority   Grid charging Grid charging
INPUT Voltage(Inverter / UPS mode) V 100-290 (± 5V) / 170-260 (± 5V) 100-290 (±5V) / 170-260 (± 5V)
  Frequency Hz 50 ± 5% (as per grid supply) 50 ± 5% (as per grid supply)
CHARGE CONTROLLER





 
Technology   Switch Switch
Precise Control   Micro Controller Based Design Micro Controller Based Design
Peak Open-Circuit Voltage V PVOC < 22.5V PVOC < 45V
Charging Mode (Float) V 13.2 / 13.8 26.4 / 27.6
Charging Mode (Boost) V 14.3 / 14.5 28.6 / 29.0
Charging Current A 7 / 10 7 / 10
Battery low cut V 10.0 ± 0.2V 20.0 ± 0.2V
No load shut down (optional)   Available (Minimum load sense : 15W) Available (Minimum load sense : 15W)
BATTERY DETAILS Nominal voltage V 12 24
Type   LMLA / SMF / Tubular LMLA / SMF / Tubular
INVERTER SPECIFICATIONS



 
Output Voltage (AC) V 220 ± 5% 220 ± 5%
Output Frequency Hz 50 ± 0.05% 50 ± 0.05%
Efficiency % > 80 > 80
Power factor   0.8 lag 0.8 lag
Wave Form type   Sine wave Sine wave
Battery low alarm V 10.4 ± 0.2V 20.4 ± 0.2V
PROTECTIONS
 
Panel / Battery Reverse   Provided through DC fuse Provided through DC fuse
No Reverse Current Flow from Battery to Solar Array   Provided Provided
Load Short Circuit   Shut Down Shut Down
INDICATIONS LED’s & BUZZER   Panel ON, Overload, Charging On, Battery Low Panel ON, Overload, Charging On, Battery Low
OVERLOAD
 
101% - 120%   7 times ON/OFF, then Shut Down 7 times ON/OFF, then Shut Down
121% - 300%   Output voltage is halved Output voltage is halved
> 300%   Immediately Shut down Immediately Shut down
GENERAL

 
Operating Temperature °C 0 to + 40 0 to + 40
Storage Temperature °C 0 to + 55 0 to + 55
Humidity % 0 to 95 0 to 95
Acoustic Noise @1 meter dB < 60 < 60

 