Air Cooled Generator Set
Air Cooled Generator Set
We are the leading trader and wholesaler of Air Cooled Generator Set which are made by using superior quality of raw materials. It has lower life cycle cost and is eco friendly. Our Air Cooled Generator Set supply power during temporary outages. They are suited to both residential and commercial environments. They are used in industry, construction, mining, agriculture, telecommunications, retail, education, IT, hospitality, and tourism, healthcare and for marine applications. These are provided at industry leading rates.
Features:-
Air cooled
Easy usage
Low on maintenance
GENSETS - 15 KVA - 30 KVA:
KIRLOSKAR 15KVA / 12KW DG sets (Silent Diesel Generator Set) Revised CPCB norms are aimed at protecting the environment by reducing Gen set emissions and improving emission quality.These are some of the most stringent emission norms in the world To meet the new norms, KOEL R & D team had choice of multiple technologies. While selecting the technology, KOEL laid significant emphasis on long term needs of users viz:
High reliability and durability of Gen sets: Owing to extreme opera & conditions in India, preference has been given to robust configurations that have been running successfully for several years
Low running costs: An effort to reduce emissions tends to increase the running costs. KOEL has succeeded in achieving both in the same design.
Optimized fuel efficiency as per actual usage: KOEL Green Gensets are tuned to provide maximum fuel efficiency in the most common operating band. At KOEL, we call it O2E series (Optimal Operating Efficiency).
Affordable, On‐site support: Proven technology ensures that product support is available close‐by, without waiting for a specialist. KOEL team has taken special efforts to keep complex technologies at bay, which may require high on‐site maintenance costs
All this, while keeping the initial costs within the reach of a smart Gen set buyer
GENSETS - 40 KVA - 125 KVA:
Technical Features:
Kirloskar 40-125 kVA Generator is equipped with 4 cylinders and 97 × 128 (Bore × Stroke) mm. The genset gives you an unmatched performance with its powerful engine. It boasts a high speed of around 1500 rpm. The genset is having microprocessor based control panel which has been designed with in-built AMF facility with a wider graphical LCD screen. Kirloskar 40-125 kVA Generator boasts of an advanced liquid cooling system with dry air filter. It is also armed with 9 Liters bare radiator coolant capacity and 50 Liters fuel tank.
Applicability:
The efficient performance and low noise level of this Kirloskar 40-125 kVA Generator makes it an ideal buy for Schools, Offices, Restaurants and homes.
Other Features:
The canopy of the Kirloskar 40-125 kVAGenerator has UV protected polyurethane powder coating for higher durability. It also comes with two point lifting provision for ease of handling and safety.
Prime and Stand‐by rating important
Engine capacity Best point
1) Prime and Stand‐by rating important :
Prime rated Gensets also permit 10% temporary overloading.
Prime power is designed for unlimited hours.
Users need to carefully select the Genset rating to meet their requirement.
2) Engine capacity Best point:
Most important part of engine is engine capacity
Best and high engine capacity is respond quickly & positively to sudden load additions.
Monitoring Features:
Phase Voltages & Currents, Frequency, Reverse power, Genset kVA , KW, KVAr , KWH, Power Factor, Canopy Temperature.
Lube oil Pressure, Engine Temperature RPM, Run Hours, No. of starts, Fuel Level, Auto / Manual Stop, AMF feature.
Battery charge condition.
Mod bus communication, Remote Monitoring.
GENSETS - 160 KVA - 250 KVA:
Prime rating and Stand‐by rating1
‘Prime power’ is designed for unlimited hours, as compared to 'Emergency stand-by' designed for 200 hours in a year. Prime rated Gensets also permit 10% temporary overloading. Users need to carefully select the Gen set rating to meet their requirement. KOEL offers Prime power as standard offer. Contact KOEL for stand-by ratings.
Phase Voltages & Currents, Frequency, Reverse power, Genset kVA , KW, KVAr , KWH,
Lube oil Pressure, Engine Temperature RPM, Run Hours, No. of starts, Fuel Level
Battery charge condition
Mod bus communication, Remote Monitoring
Battery charging failure, Over/Under speed, Over Current, Over/Under Voltage, Over KW, Phase Seq., Phase missing, Mains Under voltage, Earth Fault trip, Fuel level Alarm
Low lube oil Pressure, High Engine Temperature, Low/High battery voltage, Low Fuel Level, Over Crank protection, Routine Maint. indicator, Genset Test Facility, Mains Frequency, Fail to crank Being in control of your Genset is certainly a winning edge
GENSETS - 320 KVA - 1010 KVA:
Monitoring Features:
Phase Voltages & Currents, Frequency, Reverse power, Genset kVA , KW, KVAr , KWH, Power Factor, Canopy Temperature
Lube oil Pressure, Engine Temperature RPM, Run Hours, No. of starts, Fuel Level, Auto / Manual Stop, AMF feature Battery charge condition
Modbus communication, Remote Monitoring
Diagnostic Features:
Battery charging failure, Over/Under speed, Over Current, Over/Under Voltage, Over KW, Phase Seq., Phase missing, Mains Under voltage, Earth Fault trip, Fuel level Alarm
Low lube oil Pressure , High Engine Temperature, Low/High battery voltage, Low Fuel Level, Over Crank protection, Routine Maint. indicator, Genset Test Facility, Mains Frequency, Fail to crank.
Send Enquiry